Advantages
									Technical Data
									Downloads
									Models
									Applications
							Advantages
					- Two-stage load-control valve and bypass check valve are functionally combined in one coaxial valve assembly
 - Leak-free load holding
 - The load pressure has very little influence on the pilot pressure required → area ratio 1:66
 - Guaranteed closing force for the load-control assembly → reliable shut-off even with a broken spring
 - Thanks to the various pilot control styles, the valve can always be adapted to the system requirements
 - Hardened, ground and lapped seat valve components ensure permanent leaktightness and long service life
 - Optionally with pilot operated secondary pressure relief valve (only for housing design)
 
Technical Data
					Technical Data
| Type | Nominal flow rate l/min  | Operating pressure, dynamic bar  | Operating pressure, static bar  | Nominal size | 
|---|---|---|---|---|
| BBV | 50 | 420 | 600 | 6 | 
Downloads
					Models
					BBV 6 (with SV)


BBV 6 C, BBV 6 (without SV)


- Housing design available with / without pilot operated secondary pressure relief valve (SV)
 - Housing design with SV: SAE 1/2″ 6000 psi connection
Housing design without SV: G 3/8″ connection - No secondary pressure relief valve possible with cartridge design
 - Cartridge design: M42x1.5
 
Applications
					- Boom systems
 - Stabilizer cylinders
 - Winch drives
 - Presses
 
	

								
								
	
	
	
	
	
	
	
	
															
															
															
															
															